Comparison
| Factor | Bellows expansion joint | Flexible metal hose loop |
|---|---|---|
| Pressure thrust | Yes, unless restrained | No significant thrust |
| Main anchors | Sized for thrust (unrestrained types) | No pressure thrust on anchors |
| Guides | 4D and 14D rule plus intermediates | Guides per piping design |
| Space | Short and in line | Needs room for the loop |
| Movement | Axial, lateral or angular by type | Movement in several directions at once |
| Seismic and settlement | Limited by type | Well suited |
| Large bore, high temperature | Well suited | Size and temperature limited by hose |
Choose an expansion joint when
- Space is tight and the line is straight.
- Anchors can be designed for the thrust, or a restrained joint type fits.
- Bore size, pressure or temperature exceed what flexible hose handles.
- Movement is mostly in one direction.
Choose a flexible loop when
- Anchors are light, existing or cannot take thrust.
- Movement comes from several directions, including seismic or building settlement.
- You want to avoid pressure thrust on the anchors.
- There is room to the side or above the line.
Patriot FTS builds U-loops and V-loops in Louisiana. The expansion loop sizer estimates loop size for your movement.
What about pipe loops?
A loop made of rigid pipe and elbows also absorbs growth with no thrust, but it is much larger than a flexible hose loop for the same movement and adds pressure drop. It is common where space is free and the line is large.
Ready to quote? Use the expansion joint quote builder to enter movements, pressure and temperature and email the specification, or call (337) 573-4406. Bellows design, movement capacity, ratings and dimensions are confirmed by Patriot FTS at quote.
Frequently asked questions
What is the difference between an expansion joint and an expansion loop?
An expansion joint uses a bellows in line and develops pressure thrust unless restrained. A flexible loop bends to take movement and develops no significant thrust.
Which needs fewer anchors and guides?
A flexible loop. Unrestrained bellows joints need main anchors sized for thrust and closely spaced guides.
When is an expansion joint better?
When space is tight, the line is straight, or the bore, pressure or temperature are beyond flexible hose limits.
Can I replace an expansion joint with a loop?
Often, if there is room. Send the layout, size and movements and we will review it.