Flow Velocity and Pressure Drop Keep the flow inside the limit.

Check liquid or gas velocity in corrugated metal hose against the published limits for straight and bent hose, estimate pressure drop and see the smallest size that works. Free, no login.

Media

Water at room temperature: specific gravity 1.0, viscosity 1.0 cP. Air: molecular weight 28.96, viscosity about 0.018 cP.

Hose

Construction

How the hose is installed

Patriot FTS Flow Velocity Calculator

Result

Velocity against the limit

Installed configuration

Compare hose sizes

Same flow and length in each size. Green rows are inside the velocity limit for this configuration.

Results are preliminary engineering estimates from catalog data and published industry formulas. Patriot FTS reviews every request and confirms hose construction, live length, ratings and movement capacity on the quote.

How the flow calculator works

Corrugated metal hose has two flow limits that a smooth pipe does not. Fast flow can set the corrugations into resonant vibration and crack the hose quickly, and the corrugations add friction, so a long hose run loses more pressure than the same length of pipe. The calculator checks both.

  1. Velocity. Flow divided by the bore area at the nominal size. Gas flow in SCFM is first converted to actual flow at your inlet pressure and temperature.
  2. Velocity limit. The maximum recommended velocity for unlined hose, published across the metal hose industry, falls as the hose is bent: 150 ft/s gas and 75 ft/s liquid in a straight braided hose, down to 38 and 19 ft/s in a 180° bend. Unbraided hose limits are lower.
  3. Pressure drop. The Darcy-Weisbach equation for clean steel pipe of the same bore, with the Swamee-Jain friction factor, then multiplied by three. A drop of about three times that of comparable steel pipe is the broad rule of thumb published across the metal hose industry.
  4. Compare sizes. The table repeats the check for each size so you can see the smallest hose that stays inside the limit.

v (ft/s) = 0.4085 × gpm ÷ d² (d in inches)
ACFM = SCFM × (14.696 ÷ Pabs) × (TR ÷ 519.67)
ΔPhose ≈ 3 × f × (L ÷ D) × ρv² ÷ 2gc

ConfigurationBraided gasBraided liquidUnbraided gasUnbraided liquid
Straight150 ft/s75 ft/s100 ft/s50 ft/s
45° bend115 ft/s60 ft/s75 ft/s40 ft/s
90° bend75 ft/s40 ft/s50 ft/s25 ft/s
180° bend38 ft/s19 ft/s25 ft/s12 ft/s

When the velocity is over the limit, the usual fixes are an interlocked metal liner inside the corrugated hose, or a larger hose with reducers at each end. The calculator uses the nominal size as the bore; the actual bore varies with the corrugation profile and any liner. Pressure drop for gas is an incompressible estimate and is flagged when the drop is a large share of the inlet pressure. Hose size, liner and ratings are confirmed by Patriot FTS at quote.

Frequently asked questions

What is the maximum flow velocity in a metal hose?
For unlined braided corrugated hose the limit published across the metal hose industry is 150 ft/s for gas and 75 ft/s for liquid in a straight run. The limit falls when the hose is bent: about 75 ft/s gas and 40 ft/s liquid in a 90° bend. Unbraided hose limits are lower.
Why does flow velocity matter for corrugated hose?
High velocity can make the corrugations vibrate at their resonant frequency, which can crack the hose very quickly. An interlocked liner smooths the flow, or a larger hose lowers the velocity.
How much more pressure drop does a metal hose have than pipe?
As a broad rule of thumb, about three times the pressure drop of comparable steel pipe. The real figure depends on the corrugation profile, pitch, any liner and how the hose is routed.
Does the calculator work for gas?
Yes. Enter SCFM, inlet pressure, temperature and molecular weight. The tool converts to actual flow for the velocity check. Gas pressure drop is an estimate and is flagged when it is more than 10% of the inlet pressure.
Which hose bore does the calculator use?
The nominal size. Actual bore varies with the corrugation profile and is smaller with an interlocked liner, so Patriot FTS confirms the hose size and liner at quote.

Related tools and guides

Need it fast?

Call our on-call team any time, day or night, or send your specs online.

(337) 573-4406 Request a Quotesales@patriotfts.com
Designed. Fabricated. Tested. Delivered.  |  Built for performance. Built to last.