Minimum bend radius
Every corrugated hose has a minimum centerline bend radius. Bending it tighter over-stresses the corrugations and causes premature failure. Two values are published:
- Static applies to a hose bent once during installation and not flexed afterward.
- Dynamic applies to a hose that flexes in service, such as thermal cycling, vibration or movement. It is larger, often about twice the static value.
| Example hose | Dynamic radius | Static radius |
|---|---|---|
| 1400 series, 1/2" | 14 in | 7 in |
| 1400 series, 2" | 40 in | 20 in |
| P5, 14" | 72.5 in | 38.5 in |
Values vary by series and size. Full tables are on the pressure rating chart.
Install with the bend near the center of the hose, not at the ends.
Avoid torsion
Twisting a metal hose, even slightly, sharply reduces its life. Use two wrenches, one on the hose hex and one on the mating hex, and wrench only on the hex flats. Lap-joint (floating) flanges or unions make alignment easier without twist. Movement should be in the plane of the bend only.
No axial compression or extension
Braided hose is not designed to be pushed together or pulled apart along its length. Don't compress or stretch a hose to fit a gap. The piping must be anchored and guided so movement reaches the hose as lateral offset or bending. Remember that hose grows lengthwise under pressure, roughly 1–2%. Where axial movement is unavoidable, use a metal expansion joint or a flexible loop.
Bends at the fittings
- Don't bend the hose 90° right at the fitting. Use a 45° or 90° elbow instead.
- Allow a short straight neutral zone, about 2 in, at each end fitting before the bend begins.
- Trial-fit threaded ends by hand before wrenching.
Support and handling
- Support the piping so its weight doesn't compress the hose and relax braid tension.
- Support horizontal loop arms to prevent sag, and support loop returns so they can still move.
- Don't pre-flex the hose before installing.
- Lift, don't drag. Avoid dropping or stacking hoses, and store them away from spills and weld spatter.
- Prevent rubbing against steel, structure or other lines.
Installation checklist
- Confirm size, rating and length match the drawing.
- Check the installed bend is above the minimum radius.
- Align without twist; use two wrenches.
- Confirm no axial compression or extension.
- Anchor, guide and support the piping.
- Pressure test and check for leaks before insulating or covering.
From the Technical Reference
Tools for this job
Free tools you can use now, then email the result to Patriot FTS for a quote.
Ratings and dimensions are confirmed by Patriot FTS at quote.