Materials that stay tough in the cold
Many steels become brittle as temperature falls. Below a transition temperature they can crack with little warning under shock or bending. Austenitic stainless steels and copper alloys do not have this sharp transition, which is why they are the usual choice for cold and cryogenic hose.
| Material | Low-temperature behavior | Where it is used |
|---|---|---|
| 304, 304L, 316L and 321 stainless | Austenitic: keeps toughness down to cryogenic temperatures | Hose tube, braid, pipe nipples and fittings |
| Bronze | Copper alloy: no ductile to brittle transition | Bronze hose and braid for refrigeration and low-pressure service |
| Carbon steel, A105 | Loses toughness in the cold | Flanges to about -20°F without impact testing under common piping codes |
| Low-temperature carbon steel, A350 LF2 | Impact tested at -50°F | Flanges for moderately cold service |
Compare alloy designations in the alloy cross-reference and corrosion behavior in the alloy selection guide.
Fittings and flanges
An all-stainless hose is only as good as its weakest end. Carbon steel flanges and nipples are a common oversight on cold lines. For service below about -20°F, specify A350 LF2 flanges, and for colder service, stainless flanges and nipples. The Assembly Rating Checker lets you choose LF2 or stainless flanges and compare ratings. Gaskets and any soft seals must also suit the lowest temperature.
Thermal contraction
Stainless steel shrinks as it cools. From room temperature to liquid nitrogen temperature, austenitic stainless contracts by roughly 0.3% of its length, about 0.1 in. over 3 ft. In a rigid pipe run that contraction pulls on anchors and equipment nozzles, and a hose or loop is often there to take it. Treat cool-down as a movement: enter the temperature swing in the Expansion Loop Sizer and size the hose for the shrinkage plus any other motion.
Icing and moisture
- Ice locks the braid. Moisture from the air freezes on a cold hose. A hose that has to flex while iced can be damaged; plan the movement for warm periods or keep the hose dry.
- Frost is normal on uninsulated hose. It is not a leak sign by itself, but check for local frost spots that do not match the rest of the line.
- Keep water out of the line. Water left inside after hydrostatic testing can freeze and split a corrugation. Dry the hose after testing.
Cleanliness and purging
Cold gases are often high purity, and liquid oxygen service has strict cleanliness requirements because oil and particles can ignite. Tell us the media and any cleaning standard in your specification so it can be reviewed at quote. Purge lines with dry gas before cool-down to remove moisture and air.
What to send with a low-temperature request
- Media, and whether it is liquid, gas or two-phase.
- Minimum and maximum temperature, including warm-up and any steam-out.
- Working pressure and test pressure.
- Movement, including cool-down contraction.
- End connections and their material.
- Any cleaning, documentation or impact test requirements.