FTS-TD-102REV A · NOVEMBER 2026
Fitting Pressure Cross-Reference
Flanges · NPT · JIC · cam and groove · sanitary clamps
General screening ratings for the end connections used on hose assemblies. Connections are often rated below the hose itself, so the lowest-rated component sets the assembly working pressure. Ratings vary by material, temperature and condition; Patriot FTS confirms the actual rating of every component on the quote.
ASME Class flanges PSI at ambient temperature
| Class | Carbon steel | 304 SS | 316 SS | 304L / 316L SS |
|---|---|---|---|---|
| 150 | 285 | 275 | 275 | 230 |
| 300 | 740 | 720 | 720 | 600 |
| 600 | 1,480 | 1,440 | 1,440 | 1,200 |
| 900 | 2,220 | 2,160 | 2,160 | 1,800 |
| 1500 | 3,705 | 3,600 | 3,600 | 3,000 |
| 2500 | 6,170 | 6,000 | 6,000 | 5,080 |
Flange ratings fall with temperature. Temperature-adjusted values: patriotfts.com/flange-pressure-rating-chart.html
JIC 37° flare, SAE J514 PSI
| Dash | Nom. pipe | PSI |
|---|---|---|
| -2 | 1/8" | 5,000 |
| -3 | 1/8" | 5,000 |
| -4 | 1/8" | 5,000 |
| -5 | 1/8" | 5,000 |
| -6 | 1/4" | 5,000 |
| -8 | 3/8" | 4,000 |
| -10 | 1/2" | 3,000 |
| -12 | 3/4" | 3,000 |
| -14 | 3/4" | 2,500 |
| -16 | 1" | 2,000 |
| -20 | 1-1/4" | 1,150 |
| -24 | 1-1/2" | 1,000 |
| -32 | 2" | 1,000 |
Cam and groove PSI
| Size | PSI |
|---|---|
| 1/2" | 150 |
| 3/4"–2" | 250 |
| 2-1/2" | 150 |
| 3" | 125 |
| 4" | 100 |
| 5"–6" | 75 |
| 8" | 50 |
Assembly rule
A 200 psi hose with a 100 psi coupling is a 100 psi assembly. Rate by the lowest component, then derate for temperature.
A 200 psi hose with a 100 psi coupling is a 100 psi assembly. Rate by the lowest component, then derate for temperature.
NPT threaded fittings PSI
| Size | 316 SS / CS male | 316 SS / CS female | Brass male | Brass female |
|---|---|---|---|---|
| 1/16" | 11,050 | 6,750 | 5,550 | 3,350 |
| 1/8" | 10,050 | 6,550 | 5,050 | 3,250 |
| 1/4" | 8,050 | 6,650 | 4,050 | 3,350 |
| 3/8" | 7,850 | 5,350 | 3,950 | 2,650 |
| 1/2" | 7,750 | 4,950 | 3,850 | 2,450 |
| 3/4" | 7,350 | 4,650 | 3,650 | 2,350 |
| 1" | 5,350 | 4,450 | 2,650 | 2,250 |
| 1-1/4" | 6,000 | 5,000 | 3,000 | 2,500 |
| 1-1/2" | 5,000 | 4,600 | 2,500 | 2,300 |
| 2" | 3,900 | 3,900 | 1,900 | 1,900 |
Sanitary clamps PSI at 70°F and 250°F
| Size | Std / HD clamp 70°F | Std / HD clamp 250°F | Bolted HP clamp 70°F | Bolted HP clamp 250°F |
|---|---|---|---|---|
| 1/2"–3/4" | 1,500 | 1,200 | 1,500 | 1,200 |
| 1"–1-1/2" | 500 | 300 | 1,000 | 800 |
| 2" | 450 | 300 | 1,000 | 800 |
| 2-1/2" | 400 | 200 | 1,000 | 800 |
| 3" | 350 | 195 | 1,000 | 800 |
| 4" | 300 | 150 | 800 | 600 |
| 6" | 150 | 75 | 300 | 200 |
| 8" | 100 | 50 | 250 | 150 |
| 10" | 75 | 40 | 150 | 100 |
| 12" | 30 | 25 | 150 | 100 |
Bolted HP = high-pressure bolted clamp (13MHP style). Gasket material can further limit temperature and pressure.
Finding assembly working pressure
- Hose and braid rating (FTS-TD-101).
- End fittings: flange class, thread, coupling or clamp rating.
- Weld and attachment method.
- Gaskets and clamps.
- Temperature: derate all components for hot service.
- Service: pulsation, vibration, flexing and media.
Related: FTS-TD-101 Metal Hose Pressure Ratings · FTS-TD-103 Alloy Selection Data · FTS-TD-105 Hose Assembly Specification Worksheet · patriotfts.com/tech-reference.html